TECHNICAL MANUALINSTALLATION MANUAL FOR DOMESTIC UNITSINSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITSFOR JACKSON MODELS:HT-1HT-
5SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSINSTALLATION / OPERATION INSTRUCTIONS LT-1 & LT-3 DISPENSERSThe dishmachine is a “DUMP AND FILL” ty
6SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSINSTALLATION / OPERATION INSTRUCTIONS LT-1 & LT-3 DISPENSERS (CONTINUED)LIQUID DETERGENT DISPENSING
Installation Instructions:1. Identify the appropriate location for the box.2. Make sure the electrical supply to the dishmachine has been turned off
8SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSINSTALLATION INSTRUCTIONS & DIAGRAMS for the LT-1 & LT-31. Identify the appropriate location f
9SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCHEMICAL DISPENSING EQUIPMENT HT-1 & HT-2TO PREPARE PUMPS FOR OPERATIONThe HT-1 is a chemical dispe
10SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCHEMICAL DISPENSING EQUIPMENT LT-1 & LT-3TO PREPARE PUMPS FOR OPERATIONThe LT-1 is a chemical disp
11SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCAM TIMER OPERATION FOR HT-1The cam timer is a 2 minute 6 cam timer with an OFF-DRAIN function.The fol
12SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCAM TIMER OPERATION FOR HT-1 (CONTINUED)CAM 6: Cam 6 is an adjustable cam and controls the detergent p
13SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCAM TIMER OPERATION FOR HT-2The cam timer is a 2 minute 6 cam timer with an OFF-DRAIN function.The fol
14SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCAM TIMER OPERATION FOR HT-2 (CONTINUED)FUNCTION: The rinse aid pump cam works off the normally closed
15SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCAM TIMER OPERATION FOR LT-1The cam timer is a 2 minute 8 cam timer with an OFF-DRAIN function.The fol
16SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCAM TIMER OPERATION FOR LT-1 (CONTINUED)CAM 6: Cam 6 is an adjustable cam and controls the sanitizer p
17SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCAM TIMER OPERATION FOR LT-3The cam timer is a 2 minute 6 cam timer with an OFF-DRAIN function.The fol
18SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSCAM TIMER OPERATION FOR LT-3 (CONTINUED)CAM 6: Cam 6 is an adjustable cam and controls the sanitizer p
19SECTION 3:PARTS SECTION
20SECTION 3: PARTS SECTIONHT-1 ASSEMBLY431*721013*56141211151617910818
21SECTION 3: PARTS SECTIONHT-1 ASSEMBLY (CONTINUED)ITEM QTY DESCRIPTION Mfg. No.1 Complete HT-1 Assembly 5700-002-51-981 1 Box, Fiberglass Single Chem
41215321789104 *5161412131161591011171622SECTION 3: PARTS SECTIONHT-2 ASSEMBLY
23SECTION 3: PARTS SECTIONHT-2 ASSEMBLY (CONTINUED)ITEM QTY DESCRIPTION Mfg. No.1 Complete HT-2 Assembly, 240V 5700-031-75-621 Complete HT-2 Assembly,
ITEM QTY DESCRIPTION Mfg. No.1 Inner Panel Assembly, 240V 5700-002-10-211 Inner Panel Assembly, 115V 5700-002-84-711 1 Panel 5700-021-74-542 1 Transf
iREVISIONREVISIONDATEMADEBYAPPLICABLEECNDETAILSD 06-29-04 MAW N/A CONVERTED TO NEW LAYOUT
431*721013*5614121115161791081825SECTION 3: PARTS SECTIONLT-1 ASSEMBLY
26SECTION 3: PARTS SECTIONLT-1 ASSEMBLY (CONTINUED)ITEM QTY DESCRIPTION Mfg. No.1 Complete LT-1 Assembly 5700-031-75-601 1 Box, Fiberglass Single Chem
3514151921212216173*6189121110131978, 48, 42220201823231927SECTION 3: PARTS SECTIONLT-3 ASSEMBLY
28SECTION 3: PARTS SECTIONLT-3 ASSEMBLY (CONTINUED)ITEM QTY DESCRIPTION Mfg. No.1 Complete LT-3 Assembly, 115V 5700-031-75-611 Complete LT-3 Assembly,
29SECTION 3: PARTS SECTIONCHEMICAL FEEDER PUMP ASSEMBLYScrew, 6-32 x 3/4” Phillips Pan Head4 per5305-011-37-05Roller, Red (Detergent/Sanitizer)4320-11
30SECTION 4:ELECTRICAL SCHEMATICS
31SECTION 4: ELECTRICAL DIAGRAMSHT-1 208-240 VOLT, 60 HERTZ, SINGLE PHASETO DETERGENT SIGNAL CAM 6SMREDREDTO COMMON NEUTRAL WIREPOWER LEAD FOR PRIME
32SECTION 4: ELECTRICAL DIAGRAMSHT-2 115 VOLT, 60 HERTZ, SINGLE PHASE
33SECTION 4: ELECTRICAL DIAGRAMSHT-2 208-240 VOLT, 60 HERTZ, SINGLE PHASE
34SECTION 4: ELECTRICAL DIAGRAMSLT-1 115 VOLT, 60 HERTZ, SINGLE PHASE
iiNOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL:LT-3HT-1 = Detergent dispensing unit for high temp dishmacines.HT-2 = Detergent and rinse aid dis
35SECTION 4: ELECTRICAL DIAGRAMSLT-3 115 VOLT, 60 HERTZ, SINGLE PHASE
36SECTION 4: ELECTRICAL DIAGRAMSLT-3 240 VOLT, 60 HERTZ, SINGLE PHASE
37SECTION 5:JACKSON MAINTENANCE &REPAIR CENTERS
38SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERSALABAMA TO HAWAIIALABAMA:JONES-McLEOD APPLIANCE SVC1616 7TH AVE. NORTH BIRMINGHAM, AL 35203 (20
39SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERSIDAHO TO MISSISSIPPIIDAHO:RON'S SERVICE703 E 44TH STREET STE 10 GARDEN CITY, ID 83714 (208
40SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERSMISSISSIPPI TO NORTH CAROLINAMISSISSIPPI (cont.):GCS SERVICE INC.5755 GALLANT DRIVE.JACKSON, MS 3
41SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERSNORTH CAROLINA TO TEXASNORTH CAROLINA (cont.):AUTHORIZED APPLIANCE SERVICE CENTER109 HINTON AVE.
42SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERSTEXAS TO WYOMING/CANADATEXAS (cont.):COMMERCIAL KITCHENREPAIR CO.1377 N BRASOS P.O BOX 831128 S
iiiTABLE OF CONTENTSSECTION DESCRIPTION PAGEI. SPECIFICATION INFORMATIONDimensions 2 II. INSTALLATION/OPERATION INSTRUCTIONS Installation & Operat
1SECTION 1:SPECIFICATION INFORMATION
2SECTION 1: SPECIFICATION INFORMATIONDIMENSIONS
3SECTION 2:INSTALLATION/OPERATIONINSTRUCTIONS
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONSINSTALLATION/OPERATION INSTRUCTIONS HT-1 & HT-2 DISPENSERSMount the chemical dispenser unit in a con